      1.  

        EJA118E

        Original
        price: Negotiable
        minimum:
        Total supply:
        Delivery term: The date of payment from buyers deliver within days
        seat: Anhui
        Validity to: Long-term effective
        Last update: 2020-03-26 04:24
        Browse the number: 288
        inquiry
        Company Profile
         
         
        Product details

        1. General Introduction

        EJA118E Diaphragm Sealed Differential Pressure Transmitters can be used to measure liquid, gas, or steam flow, as well as liquid level, density, and pressure. It's diaphragm seals are used to prevent process medium form entering directly into the pressure-sensing assembly, connected to the transmitter using capillaries filled with fill fluid, available for fluid with temperature -50 to 310°C.


        2. Measuring Span & Range limits

        Measurement Span/Range

        kPa

        inH2O

        (/D1)

        mbar

        (/D3)

        ?

        mmH2O

        (/D4)

        ?

        M

        Span

        2.5 to 100

        10 to 400

        25 to 1000

        250 to

        10000


        Range

        -100 to

        100

        -400 to

        400

        -1000 to

        1000

        -10000 to

        10000

        ?

        H

        Span

        25 to 500

        100 to

        2000

        250 to

        5000

        0.25 to 5

        kgf/cm2


        Range

        -500 to

        500

        -2000 to

        2000

        -5000 to

        5000

        -5 to 5

        kgf/cm2


        3. Process temperature, Ambient temperature, and Working pressure

        Liquid Fill

        Code

        Process temperature*

        Ambient temperature*

        Working pressure

        Silicone oil

        (general use)

        A

        10 to 250°C

        (14 to 482°F)

        10 to 60°C

        (14 to 140°F)

        2.7 kPa abs

        (0.38 psi abs)

        to flange rating pressure

        Silicone oil

        (general use)

        B

        30 to 180°C

        (22 to 356°F)

        15 to 60°C

        (5 to 140°F)

        Silicone oil

        (high ? temperature use)

        C

        10 to 310°C

        (50 to 590°F)

        10 to 60°C

        (50 to 140°F)

        Fluorinated oil

        (oil-prohibited ? use)

        D

        20 to 120°C

        (4 to 248°F)

        10 to 60°C

        (14 to 140°F)

        51 kPa abs

        (7.4 psi abs)

        to flange rating pressure

        Ethylene glycol

        (low temperature ? use)

        E

        50 to 100°C

        (58 to 212°F)

        40 to 60°C

        (40 to 140°F)

        100 kPa abs

        (atmospheric pressure)

        to flange pressure rating

        Silicone oil

        (high temp. and ? high

        vacuum use)

        1

        10 to 250°C

        (14 to 482°F)

        10 to 60°C *

        (14 to 140°F)

        0.013 kPa abs

        (0.0019 psi abs)

        to flange rating pressure

        Silicone oil

        (high temp. and ? high

        vacuum use)

        2

        10 to 310°C

        (50 to 590°F)

        10 to 60°C

        (50 to 140°F)

        Silicone oil

        (high vacuum use)

        4

        10 to 100°C

        (14 to 212°F)

        10 to 60°C

        (14 to 140°F)


        4. Flange size and rating

        Process

        connection style

        Size

        Flange

        Flush type

        3-inch,

        2-inch,

        11/2-inch

        JIS 10K, 20K, 40K

        ANSI Class 150, 300, 600

        JPI Class 150, 300, 600

        DIN PN10/16, ? 25/40, 64

        Extended type

        4-inch, 3-inch

        JIS 10K, 20K

        ANSI Class 150, 300

        JPI Class 150, 300

        DIN PN10/16, ? 25/40

        Combination type ? (Extended and Flush)

        High pressure side: ? 4-inch, Low pressure side: 3-inch

        JIS 10K, 20K

        ANSI Class 150, ? 300

        JPI Class 150, ? 300

        DIN PN10/16, ? 25/40


        5. Model and suffix codes

        ◆ Instruction

        The model and suffix codes for EJA118E consist of two parts; a transmitter body section (I) and a diaphragm seal section (II). This specification sheet introduces these two parts separately. The transmitter body section is shown in one table, and the diaphragm seal section specifications are listed according to the process connection style. First select the model and suffix codes of transmitter body section and then continue on one of the diaphragm seal selection.


        5.1. Transmitter body section

        Main Code

        Suffix Codes

        Description

        EJA118E











        Diaphragm sealed ? differential pressure transmitter

        Output signal

        -D










        4 to 20 mA DC with ? digital communication (BRAIN protocol)

        -J










        4 to 20 mA DC with digital ? communication (HART 5/HART 7 protocol)

        -F










        Digital communication ? (FOUNDATION Fieldbus protocol)

        -G










        Digital communication ? (PROFIBUS PA protocol)

        -Q










        Low Power, 1 to 5 V DC ? with digital communication (HART 7 protocol)

        Measurement

        span (capsule)


        M









        2.5 to 100 kPa (10 to ? 400 inH2O)


        H









        25 to 500 kPa (100 to ? 2000 inH2O)



        S








        Always S




        C







        Always C

        Cover flange bolts and ? nuts

        material





        J






        B7 carbon steel





        G






        316L SST





        C






        660 SST

        Installation






        -9





        Horizontal ? piping and left side high pressure

        Amplifier housing







        1




        Cast aluminum alloy







        3




        Cast aluminum alloy ? with corrosion resistance properties







        2




        ASTM CF-8M stainless ? steel

        Electrical connection








        0



        G1/2 ? female, one electrical connection without blind plugs








        2



        1/2 ? NPT female, two electrical connections without blind plugs








        4



        M20 ? female, two electrical connections without blind plugs








        5



        G1/2 ? female, two electrical connections and a blind plug








        7



        1/2 ? NPT female, two electrical connections and a blind plug








        9



        M20 ? female, two electrical connections and a blind plug








        A



        G1/2 ? female, two electrical connections and a SUS316 blind plug








        C



        1/2 ? NPT female, two electrical connections and a SUS316 blind plug








        D



        M20 ? female, two electrical connections and a SUS316 blind plug

        Integral indicator









        D


        Digital indicator









        E


        Digital indicator with ? the range setting switch (push button)









        N


        None

        Mounting bracket










        B

        304 ? SST 2-inch pipe mounting, flat type (for horizontal piping)










        J

        316 ? SST 2-inch pipe mounting, flat type (for horizontal piping)

        Optional codes

        /Optional codes


        5.2. Diaphragm seal section (Flush type)

        ◆ Process connection size: 3-inch (80 mm) / 2-inch (50 mm)

        Main Code

        Suffix Codes

        Description

        EJA118E













        Transmitter body ? section (I)

        Process connection style

        -W












        Flush type

        Flange rating


        J1











        JIS 10K


        J2











        JIS 20K


        J4











        JIS 40K


        A1











        ANSI class 150


        A2











        ANSI class 300


        A4











        ANSI class 600


        P1











        JPI class 150


        P2











        JPI class 300


        P4











        JPI class 600

        Process connection size

        (Process flange size)



        3










        3-inch (80 mm)



        2










        2-inch (50 mm)

        Flange material




        A









        JIS S25C




        B









        304 SST




        C









        316 SST

        Gasket contact surface





        1








        Serration (for ? ANSI flange with wetted parts material SW only)





        2








        Flat (no ? serration)

        Wetted parts material






        SW







        316L SST Diaphragm, 316L SST Others






        HW







        Hastelloy C-276 Diaphragm, Hastelloy C-276 Others






        TW







        Tantalum Diaphragm, Tantalum Others






        UW







        Titanium Diaphragm, Titanium Others

        Flushing connection ring







        0






        None







        1






        Straight type ? ring, R1/4 connections, 316 SST







        2






        Straight type ? ring, 1/4NPT connections, 316 SST

        Extension








        0





        None

        Fill fluid









        -A




        For general ? (silicone oil), Process10 to 250°C, Ambient10 to 60°C









        -B




        For general ? (silicone oil), Process30 to 180°C, Ambient15 to 60°C









        -C




        For high ? temperature (silicone oil), Process10 to 310°C, Ambient10 to ? 60°C









        -D




        For ? oil-prohibited (fluorinated oil), Process-20 to 120°C, Ambient-10 to ? 60°C









        -E




        For low ? temperature (ethylene glycol), Process-50 to 100°C, Ambient-40 to ? 60°C









        -1




        For high temp. ? & vacuum (silicone oil), Process-10 to 250°C, Ambient-10 to ? 60°C









        -2




        For high temp. ? & vacuum (silicone oil), Process10 to 310°C, Ambient10 to ? 60°C









        -4




        For high vacuum ? (silicone oil), Process-10 to 100°C, Ambient-10 to ? 60°C

        Capillary connection










        A



        Side of diaphragm seal unit











        2


        Always 2

        Capillary length*












        1

        1m












        2

        2m












        3

        3m












        4

        4m












        5

        5m












        6

        6m












        7

        7m












        8

        8m












        9

        9m












        A

        10m

        Optional codes

        /Optional codes


        5.3. Diaphragm seal section (Flush type)

        ◆ Process connection size: 1-1/2inch (40 mm)

        Main Code

        Suffix Codes

        Description

        EJA118E













        Transmitter body ? section (I)

        Process connection style

        -W












        Flush type

        Flange rating


        J1











        JIS 10K


        J2











        JIS 20K


        J4











        JIS 40K


        A1











        ANSI class 150


        A2











        ANSI class 300


        A4











        ANSI class 600


        P1











        JPI class 150


        P2











        JPI class 300


        P4











        JPI class 600

        Process connection size

        (Process flange size)



        8










        1-1/2-inch (40 ? mm)

        Flange material




        A









        JIS S25C




        B









        304 SST




        C









        316 SST

        Gasket contact surface





        1








        Serration (for ? ANSI flange with wetted parts material SW only)





        2








        Flat (no ? serration)

        Wetted parts material






        SW







        316L SST Diaphragm, 316L SST Others

        Flushing connection ring







        3






        Reducer type ? ring, R1/4 connections, 316 SST







        4






        Reducer type ? ring, 1/4NPT connections, 316 SST

        Extension








        0





        None

        Fill fluid









        -A




        For general ? (silicone oil), Process10 to 250°C, Ambient10 to 60°C









        -B




        For general ? (silicone oil), Process30 to 180°C, Ambient15 to 60°C









        -D




        For ? oil-prohibited (fluorinated oil), Process-20 to 120°C, Ambient-10 to ? 60°C









        -E




        For low ? temperature (ethylene glycol), Process-50 to 100°C, Ambient-40 to ? 60°C









        -1




        For high temp. ? & vacuum (silicone oil), Process-10 to 250°C, Ambient-10 to ? 60°C









        -4




        For high vacuum ? (silicone oil), Process-10 to 100°C, Ambient-10 to ? 60°C

        Capillary connection










        A



        Side of diaphragm seal unit











        2


        Always 2

        Capillary length*












        1

        1m












        2

        2m












        3

        3m












        4

        4m












        5

        5m












        6

        6m












        7

        7m












        8

        8m












        9

        9m












        A

        10m

        Optional codes

        /Optional codes


        5.4. Diaphragm seal section (Extended type)

        ◆ Process connection size: 4-inch (100 mm) / 3-inch (80 mm)

        Main Code

        Suffix Codes

        Description

        EJA118E













        Transmitter body ? section (I)

        Process connection style

        -E












        Extended type

        Flange rating


        J1











        JIS 10K


        J2











        JIS 20K


        A1











        ANSI class 150


        A2











        ANSI class 300


        P1











        JPI class 150


        P2











        JPI class 300


        D2











        DIN PN10/16


        D4











        DIN PN25/40

        Process connection size

        (Process flange size)



        4










        4-inch (100 mm)



        3










        3-inch (80 mm)

        Flange material




        A









        JIS S25C




        B









        304 SST




        C









        316 SST

        Gasket contact surface





        1








        Serration (for ? ANSI flange with wetted parts material SW only)





        2








        Flat (no ? serration)

        Wetted parts material






        SE







        316L SST Diaphragm, 316L SST Others

        Flushing connection ring







        0






        None

        Extension








        2





        Length (X2) = 50 mm








        4





        Length (X2) = 100 mm








        6





        Length (X2) = 150 mm

        Fill fluid









        -A




        For general ? (silicone oil), Process10 to 250°C, Ambient10 to 60°C









        -B




        For general ? (silicone oil), Process30 to 180°C, Ambient15 to 60°C









        -C




        For high ? temperature (silicone oil), Process10 to 310°C, Ambient10 to ? 60°C









        -D




        For ? oil-prohibited (fluorinated oil), Process-20 to 120°C, Ambient-10 to ? 60°C









        -E




        For low ? temperature (ethylene glycol), Process-50 to 100°C, Ambient-40 to ? 60°C









        -1




        For high temp. ? & vacuum (silicone oil), Process-10 to 250°C, Ambient-10 to ? 60°C









        -2




        For high temp. ? & vacuum (silicone oil), Process10 to 310°C, Ambient10 to ? 60°C









        -4




        For high vacuum ? (silicone oil), Process-10 to 100°C, Ambient-10 to ? 60°C

        Capillary connection










        B



        Back of diaphragm seal unit











        2


        Always 2

        Capillary length*












        1

        1m












        2

        2m












        3

        3m












        4

        4m












        5

        5m












        6

        6m












        7

        7m












        8

        8m












        9

        9m












        A

        10m

        Optional codes

        /Optional codes


        5.5. Diaphragm seal section (Combination type)

        ◆ Process connection size:

        High pressure side; 4-inch (100 mm) ? ? ? Extended type

        Low pressue side; 3-inch (80 mm) ? ? ? Flush type

        Main Code

        Suffix Codes

        Description

        EJA118E













        Transmitter body ? section (I)

        Process connection style

        -Y












        Combination type ? (Extended and Flush)

        Flange rating


        J1











        JIS 10K


        J2











        JIS 20K


        A1











        ANSI class 150


        A2











        ANSI class 300


        P1











        JPI class 150


        P2











        JPI class 300


        D2











        DIN PN10/16


        D4











        DIN PN25/40

        Process connection size

        (Process flange size)



        W










        High pressure ? side 4-inch (100 mm), Low pressure side 3-inch (80 mm)

        Flange material




        A









        JIS S25C




        B









        304 SST




        C









        316 SST

        Gasket contact surface





        1








        Serration (for ? ANSI flange with wetted parts material SW only)





        2








        Flat (no ? serration)

        Wetted parts material






        SY







        316L SST Diaphragm, 316L SST Others

        Flushing connection ring







        0






        None

        Extension








        1





        Length (X2) = 50 mm








        3





        Length (X2) = 100 mm








        5





        Length (X2) = 150 mm

        Fill fluid









        -A




        For general ? (silicone oil), Process10 to 250°C, Ambient10 to 60°C









        -B




        For general ? (silicone oil), Process30 to 180°C, Ambient15 to 60°C









        -C




        For high ? temperature (silicone oil), Process10 to 310°C, Ambient10 to ? 60°C









        -D




        For ? oil-prohibited (fluorinated oil), Process-20 to 120°C, Ambient-10 to ? 60°C









        -E




        For low ? temperature (ethylene glycol), Process-50 to 100°C, Ambient-40 to ? 60°C









        -1




        For high temp. ? & vacuum (silicone oil), Process-10 to 250°C, Ambient-10 to ? 60°C









        -2




        For high temp. ? & vacuum (silicone oil), Process10 to 310°C, Ambient10 to ? 60°C









        -4




        For high vacuum ? (silicone oil), Process-10 to 100°C, Ambient-10 to ? 60°C

        Capillary connection










        B



        Back of diaphragm seal unit for high pressure side, side of diaphragm ? seal unit for low pressure side,











        2


        Always 2

        Capillary length*












        1

        1m












        2

        2m












        3

        3m












        4

        4m












        5

        5m












        6

        6m












        7

        7m












        8

        8m












        9

        9m












        A

        10m

        Optional codes

        /Optional codes


        6. Mounting & Dimensions

        ◆ Transmitter body section

        ◆ Diaphragm seal section


        ● Flush type

        ● Extended type

        ● Combination type


        7. Ordering Information

        Specify the following when ordering:

        1. Model, suffix codes, and option codes

        2. Calibration range and units:1) Calibration range can be specified with range value specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of -32000 to 32000. When reverse range is designated, specify LRV as greater than URV. When square root output mode is specified, LRV must be "0(zero)". 2) Specify only one unit from the table.

        3. Select linear or square root for output mode and display mode. Note: If not specified, the instrument is shipped set for linear mode.

        4. Display scale and units (for transmitters equipped with the integral indicator only) Specify either 0 to 100 % or 'Range and Unit' for engineering units scale: Scale range can be specified with range limit specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of -32000 to 32000. Unit display consists of 6-digit, therefore, if the specified scaling unit excluding '/' is longer than 6-characters, the first 6 characters will be displayed on the unit display.

        5. HART PROTOCOL: When output signal code is "J", specify the HART protocol revision "5" or "7".

        6. TAG NO (if required): Specified characters (up to 16 characters for BRAIN, 22 characters for HART) are engraved on the stainless steel tag plate fixed on the housing.

        7. SOFTWARE TAG (for HART only. if required) Specified characters (up to 32 characters) are set as "Tag" (the first 8 characters) and "Long tag(32 characters) in the amplifier memory. Use alphanumeric capital letters. When the "SOFTWARE TAG" is not specified, specified "TAG NO" is set as "Tag" (the first 8 characters) and "Long tag"*1 (22 characters) in the amplifier memory.

        8. Other factory configurations (if required): Specifying option code CA or CB will allow further configuration at factory. Following are configurable items and setting range. [/CA : For HART communication type]: 1) Descriptor (up to 16 characters), 2) Message (up to 30 characters), 3) Software damping (0.00 to 100.00 s) [/CB : For BRAIN communication type]: 1) Software damping (0.00 to 100.00 s).

        9. Process fluid temperature for zero compensation: (When /R is specified.)